China Supply Made in China Online UPS High Frequency Type voor Computer Home UPS

Beschrijving P1K(L)-P3K(L) ONLINE HIGH FREQUENCY UPS Function FeaturesTrue double-conversion online UPSMicroprocessor control optimizes reliabilityOutput power factor0.8Wide Input volt

Featured Products

Beschrijving

P1K(L)-P3K(L) ONLINE HIGH FREQUENCY UPS

Function Features
True double-conversion online UPS
Microprocessor control optimizes reliability
Output power factor0.8
Wide Input voltage range(110V - 300VAC)
Input power factor correction
Converter mode available
ECO mode for energy saving
Generator compatible
Smart SNMP works well with either USB or RS-232 together
Comprehensive display allows easy monitoring and access of UPS status


Specification


MODEL

P1K(L)

P2K(L)

P3K(L)

PHASE

Single phase with ground

CAPACITY

1000VA/ 800W

2000VA/ 1600W

3000VA / 2400W

INPUT

Nominal Voltage

100/110/115/120/127VAC or 200/208/220/230/240VAC

Input Voltage Range

55~150 VAC or 110-300VAC at 50% load 85-140 VAC or 160-280VAC at 100% load

Frequency Range

40Hz ~ 70Hz

Power Factor

>=0.99@ Nominal voltage(100% load)

OUTPUT

Output Voltage

100/110/115/120/127VAC or 200/208/220/230/240VAC

Voltage Regulation

±1%

Frequency Range(Synchronized Range)

47-53 Hz or 57~63 Hz

Frequency Range(Batt. Mode)

50 Hz±0.25Hz or 60Hz±0.3 Hz

Current Crest Ratio

3 : 1

Harmonic Distortion

<=3% THD(Linear Load), <=6% THD(Non-linear Load)

Transfer
Time

AC to DC

Zero

Inverter to Bypass

4ms(Typical)

Waveform(Batt. Mode)

Pure Sine wave

EFFICIENCY

To AC Mode

88%

88%

90%

To Battery Mode

83%

85%

88%

BATTERY

Standard
Model

Battery Type

12V/7Ah

12V/7Ah

12V/7Ah

Numbers

2

4

6

Typical Recharge Time

4 hours recover to 90% capacity

Charging Current(max.)

1.0A

Charging Voltage

27.4VDC±1%

54.7VDC±1%

82.1VDC±1%

Long-run
Model

Battery Numbers

Depending on the capacity of external batteries

Charging Current(max.)

1A-6A(Adjustable)

Charging Voltage

41.0VDC±1%

82.1VDC±1%

109.4VDC±1%

INDICATORS

LCD

Load level, Battery level, AC mode, Bypass mode, and Fault indicators

PHYSICAL

Standard
Model

Dimension, D×W×H(mm)

397×145×220

419×190×318

Net Weight(kgs)

9.8

17

23

Long-run
Model

Dimension ,D×W×H(mm)

282×145×220

397×145×220

Net Weight(kgs)

3.97

6.7

7.24

ENVIRONMENT

Humidity

20-90% RH@ 0-40ºC(Non-condensing)

Noise Level

Less than 50dBA@ 1 Meter

MANAGMENT

Smart RS-232/USB

Support Windows@2000/2003/XP/Vista/2008, Windows@7/8, Linux, Unix, and MAC

Optional SNMP

Power management from SNMP manager and web browser

P6K(L)/P10K(L) ONLINE HIGH FREQUENCY UPS

Function Features
True double-conversion online UPS
DSP technology guarantees high performance
Output power factor 0.8
Standard backup UPS and long backup UPS in one integrated unit
Adjustable charging current via LCD or software(0.5A-6A)
Wide input voltage range(110-300VAC)
Active Input power factor correction 0.99
Emergency power off function(EPO)

Specification

MODEL

P6K(L)

P10K(L)

PHASE

Single phase with ground

CAPACITY

6000VA/ 4800W

10000VA / 8000W

INPUT

Nominal Voltage

208/220/230/240VAC

Input Voltage Range

110-300 VAC at 50% load ,178-300 VAC at 100% load

Frequency Range

46~54Hz or 56~64Hz

Power Factor

>=0.99@ Nominal voltage(100% load)

OUTPUT

Output Voltage

208/220/230/240VAC

Voltage Regulation

±1%

Frequency Range(Synchronized Range)

46~54 Hz or 56-64 Hz

Frequency Range(Batt. Mode)

50 Hz or 60Hz ±0.1 Hz

Current Crest Ratio

3 : 1

Harmonic Distortion

<=3% THD(Linear Load), <=5% THD(Non-linear Load)

Transfer
Time

AC to DC

Zero

Inverter to Bypass

Zero

Waveform(Batt. Mode)

Pure Sine wave

EFFICIENCY

To AC Mode

92%

90%

To Battery Mode

90%

89%

BATTERY

Standard
Model

Battery Type

12V/7Ah

Numbers

16

Typical Recharge Time

9 hours recover to 90% capacity

Charging Current(max.)

1.0A

Charging Voltage

218.4VDC±1%

Long-run
Model

Battery Numbers

Depending on the capacity of external batteries

Charging Current(max.)

1A, 2A, 4A, 6A(Adjustable)

Default:4.0A± 10%

Charging Voltage

218.4VDC±1%

INDICATORS

LCD

Load level, Battery level, AC mode, Bypass mode, and Fault indicators

PHYSICAL

Standard
Model

Dimension,D×W×H(mm)

369×190×688

442×190×688

Net Weight(kgs)

60

66

Long-run
Model

Dimension,D×W×H(mm)

369×190×318

442×190×318

Net Weight(kgs)

12

16

ENVIRONMENT

Humidity

0-95% RH@ 0-50ºC(Non-condensing)

Noise Level

Less than 58dBA@1 Meter

MANAGMENT

Smart RS-232/USB

Support Windows@2000/2003/XP/Vista/2008, Windows@7/8, Linux, Unix, and MAC

Optional SNMP

Power management from SNMP manager and web browser


P10K(L)(3/1)-P20K(L)(3/1) ONLINE HIGH FREQUENCY UPS

Function Features
True double-conversion online UPS
DSP technology guarantees high performance
Output power factor0.8
Wide Input voltage range(110V - 300VAC)
Active power factor correction in all phases
50Hz/60Hz frequency converter mode
ECO mode for energy saving
Generator compatible
Programmable power management outlets
Emergency power off function(EPO)
Charger capacity expansion to 8A for long-run models
3-stage extendable charging design for optimized battery performance
SNMP+USB+RS-232 multiple communications
Maintenance bypass available
Optional N+X parallel redundancy

Specification

MODEL

3P10KL

3P15KL

3P20KL

PHASE

3- phase in/ 1-phase out

CAPACITY

10000VA/ 8000W

15000VA/ 12000W

20000VA / 16000W

INPUT

Input Voltage Range

305~478 VAC (3-phase) at 100% load 190-520 VAC ( 3-phase) at 50% load

Frequency Range

46-54Hz or 56-64Hz

Power Factor

>=0.99@ Nominal voltage(100% load)

OUTPUT

Output Voltage

208/220/230/240VAC

Voltage Regulation

±1%

Frequency Range(Synchronized Range)

46-54 Hz or 56~64 Hz

Frequency Range(Batt. Mode)

50 Hz±0.1Hz or 60Hz±0.1 Hz

Current Crest Ratio

3 : 1

Harmonic Distortion

<=2% THD(Linear Load), <=5% THD(Non-linear Load)

Transfer
Time

AC to DC

Zero

Inverter to Bypass

Zero

Waveform(Batt. Mode)

Pure Sine wave

EFFICIENCY

To AC Mode

89%

89%

89%

To Battery Mode

86%

88%

87%

BATTERY

Long-run
Model

Battery Numbers

Depending on the capacity of external batteries

Charging Current(max.)

4A

4A

Charging Voltage

218.4VDC±1%

INDICATORS

LCD

UPS status, Load level, Battery level, Input / Output voltage, Discharge timer, and Fault indicators

PHYSICAL

Long-run
Model

Dimension ,D×W×H(mm)

592×250×576

592×250×576

Net Weight(kgs)

28

40

40

ENVIRONMENT

Humidity

20-90% RH@ 0-40ºC(Non-condensing)

Noise Level

Less than 50dBA@ 1 Meter

MANAGMENT

Smart RS-232/USB

Support Windows@2000/2003/XP/Vista/2008, Windows@7/8, Linux, Unix, and MAC

Optional SNMP

Power management from SNMP manager and web browser

*Derate capacity to 60% of capacity in CVCF mode and to 90% when the output voltage is adjusted to 208VAC.



FAQ

Q 1. what's the payment terms?
A. We accept LC, T/T, PayPal, Western Union, Small-amount payment, Money Gram
Q 2. how's the delivery time ?
A. usually it will take about two weeks for production
Q 3. tell me the standard of package?
A. For the small capacity, it use carton, but for big capacity, we should use strong wooden case for protection.
Q 4. what kind of material of transformer?
A. For servo type stabilizer,we have two types, one 100% copper and the other is copper with aluminum.It depends on your requirment. In fact,those two have no difference if normal work well. Only except the longlife. Copper is better and also higer price.For relay type stabilizer,we use toroid coils, the material is aluminum. comparing with square coils,toriod coils with high efficiency.
Q 5.Could you offer Form A or C/O ?
A. It totally not a problem. We can prepare relative documents to forgin affairs office or other office to apply for this certificate.
Q 6.Would you accept to use our logo ?
A.If you have good quantity,it absolute no problem to do OEM.
Q 7.We want to know month capacity.
A. It depends on which model.For example for relay type small capacity , month capacity can reach near 10000pcs and big capacity near 2000pcs.
Q 8.Where is your market?
A. Our products are popular inNorth America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europeand so on.Some of them are our regular customers and some of them are developing. We hope you can join us and make mutural benifit from our cooperation.
Q 9. what kind of certificate you have ?
A. Our company already achieve ISO9001, and for products, we have CE,ISO9001,SGS,Son cap



Company Information
ZHEJIANG TTN ELECTRIC CO., LTD

1)We are professional manufacturer of Voltage Stabilizer/Car power inverter/UPS/Solar control system founded in 1994 year with 33,000 square meter building.
2)We have best Research/Development Department,one of our technician have more than 20years experience produce voltage stabilizer .
3) We have strictly Test systems and equipment of PCBA/transformer/finished product,check each step,each article goes through a strategic pass,lets the users be satisfied.
4 ) As manufacturer we have 12product lines, daily output 2500pcs. We can expedite for you every day, guarantee not delay your delivery time.
5 )Best OEM/ODM service.

Neem contact met ons op

Aarzel niet om uw vraag te stellen in het onderstaande formulier. We zullen u binnen 24 uur antwoorden!